1½ STOREY SEMI-DETACHED FACTORY

TYPE A
1½ STOREY SEMI-DETACHED FACTORY

[SOLD OUT]

LAND AREA
Approx. 18,674.46 - 21,440.81 sq.ft
GROSS FLOOR AREA
Approx. 12,073 - 12,391 sq.ft
Factory Height
:
9 m
Floor Design Loads
Production Area (Ground Floor)
:
20kN/m², Non-Suspended Floor Slab
Office Area (Mezzanine Floor)
:
2.5kN/m²
Roof Design Loads
Production Area Roof
:
Imposed dead load = 0.25kN/m² (Load of Rafter, Purlin, Metal Roofing Sheet, Insulation, Lighting Fitting and Gypsum Board Ceiling with Aluminium Tee Frame)
Live load = 0.25kN/m²
Roof Systems
Roof Structure
:
Structural Steel Designed to BS 5950 Standard
Roof Sheets
:
Galvalume Metal Roof or Equivalent c/w 50mm Thick Fiberglass Insulation
Rain Water Down Pipe
:
Exposed 150mm Ø UPVC Pipe (Production Area)
Concealed 150mm Ø UPVC Pipe (Office Area)
Gutter
:
Stainless Steel Gutter
Walls
Internal Wall (Office and Sprinkler Tank Area)
:
115mm Thick Common Brick Wall with Plaster and Painted with Emulsion Paint.
:
Ceramic Wall Tiles to Toilets (2.1m High)
External Wall (Office Area)
:
115mm Thick Common Brick Wall with Plaster and Painted with Weather Bond Paint.
External Wall (Production Area)
:
Brick Wall and/or Precast Wall and Painted with Weather Bond Paint
Floors
Ground Floor
:
150mm Thick G30 Concrete with a Layer of Polythene Sheet and BRC A7
Production Finishes
:
4kg/m² Floor Harderner Finishes
Office & Lobby Finishes
:
Polished Tiles
Lobby Staircase Finishes
:
Polished tiles
Toilet Floor Finishes
:
Matt Surface Ceramic Tiles
Doors
External Doors
:
Motorized Roller Shutters and Mild Steel Doors (Production Area)
:
Tempered Glass Door (Entrance Area)
Internal Doors
:
Fire-rated Door (Based on Local Authority Requirement) & Timber Flush Door (Office Area)
Windows
External Windows
:
NA Aluminium Casement Window (Production Area)
:
Reflective Glass Curtain Wall (Office Area)
:
Aluminium Framed Top Hung Windows (Office Area)
Ceiling
Office Area
:
2ft x 4ft Gypsum Pin Hole False Ceiling (Office Area)
:
Gypsum Board Plaster Ceiling (Lobby Area)
Production Area
:
Exposed Steel Structure (No Ceiling)
Infrastructure Works
External Road
:
150mm Thick Reinforced Concrete Road c/w road marking
Parking Bays
:
150mm Thick Reinforced Concrete Road c/w parking lot
Fencing
:
Front Signage : 7.5m Length Common Brick Wall with c/w Plaster Cement and Painted with Weatherbond Paint
:
Perimeter : 150mm High Kerb with 1.8m High BSP Fencing
Gate
:
7.5m Wide Sliding Gate Without Motor
:
Power Point for Motor Provided
Drainage System
:
Concealed Pipe Culvert Drain
Sewerage System
:
Vitrified Clay Pipe (VCP) Connect to Main Sewerage Line
Bin Center
:
1 no.
Hose Reel Tank & Plinth
:
1 no.
Standard Mechanical & Electrical Specification
MSB 400A (Setting 200A)
:
1 no.
DB 150A
:
1 no.
DB 60A
:
2 nos.
Lighting Point
:
58 nos.
13A S/S/O
:
29 nos.
15A Air-Cond Power Point
:
3 nos.
Emergency Light
:
12 nos.
Keluar' Sign
:
8 nos.
Telephone Point
:
2 nos.
Data Point
:
2 nos.
30A Isolator Point
:
3 nos.
Fire Protection Systems
Fire Alarm System
:
Yes
Hosereel System
:
Yes
Portable Fire Extinguisher
:
Yes
Plumbing & Water Recticulation Systems
Water Tank for Toilet only
:
Yes
Incoming Domestic Piping & Discharged Piping
:
Yes

The information contained in this loose sheet is subject to change and cannot form part of an offer or contract. All renderings are artist’s impression only. While every reasonable care has been taken in preparing this loose sheet, the developer cannot be held responsible for any inaccuracies. All the above items are subject to variations, modifications, and substitutions as may be required by authorities or recommended by the Architect or Engineer.